Fourth, the computer board indicates the working status. A Kitchen Faucet (also spigot or tap: see usage variations) is a valve controlling the release of a liquid that enabling washing and drying in the kitchen. Kitchen Faucet,Long Spout Kitchen Faucet,Hot And Cold Water Kitchen Faucet,Spray Paint Grey Kitchen Faucet Kaiping Jenor Sanitary Ware Co., Ltd , https://www.jmjenorsanitary.com
a. The water lamp corresponds to the operation of the high pressure pump, the water inlet solenoid valve opens the water inlet, and the pure water machine normally produces water.
b. The flushing lamp corresponds to the flushing solenoid valve, and the membrane is subjected to high pressure and large flow flushing.
c. Full water light, corresponding to the high pressure switch, the pressure tank is full of water, cut off the power supply.
d, power light. The system is powered normally and the power indicator is steady on.
Computer board plugs a total of 12 lines:
a, the yellow line is connected to the low switch;
b. Two lines of blue line are connected to the high voltage switch;
c. Two black lines are connected to the water solenoid valve;
d, two lines of red line flushing solenoid valve;
e, the green line is connected to the high pressure pump;
f, powder line, white line connected to the power supply.
V. Precautions before installation First check the label of the outer packaging of the pure water machine, whether it is the same as the model required by the demander; check the delivery unit or the sales invoice and the telephone number of the buyer's name; the requirement is that the outer packaging has no leakage or damage; Require the identification and model to be consistent with customer requirements. Secondly, after opening the package, check whether the parts of the split box, the warranty card, the manual and the certificate are complete, and whether there is any defect.
2. Check the whole machine, first check the water pipe, whether it is firm or loose, all the water pipes should be firm, the color is uniform, there must be no kinks, dead bends, cracks, etc., then check the circuit, the transformer is connected and connected. No exposed parts, computer board wiring is correct, no naked or wrong connection, check whether the spring is connected, should be connected firmly, with or without falling off, check whether the high and low voltage switch is broken, whether the high pressure switch pressure screw is off; check into Water, flush the solenoid valve with or without the exposed part of the coil; check other accessories again, no damage is required, and a shortage occurs.
Sixth, the installation notes:
1, pay attention to service attitude, to be modest, kind and effective communication and communication with users.
2. Installers bring their own shoe covers, gloves and rags.
3, the choice of installation location on the one hand to facilitate installation, but also easy to repair and maintenance. It varies from person to person, from person to person, from actual situation, proposes our plan, and respects the user's thoughts.
4, whether it is placed in the position, or to bind the water pipe, we must pay attention to the appearance and practical.
5. If you need to wear a wall, or punch holes in countertops, cabinets, etc., pay attention to maintaining its integrity, and be reasonable and beautiful. If the situation cannot be controlled, you should first inform the user of the possible consequences and damages. Get their consent. The same is true when accessing the water tee.
6. When installing the machine, first clean the space of the machine, and the surrounding environment must not be dirty when the machine is installed.
7. Turn on the water source first, and then turn on the power when the machine is full.
8. After the installation is completed, the user should be informed of the method of use and precautions, and inform the user of the abnormal situation that may occur, and propose an emergency treatment.
9. After the installation is completed, carefully check and debug, and do a basic registration to ensure that everything is normal and leave the site.
7. Install the machine (1) Select a reasonable installation position, as close as possible to the water source, power supply and drain port, and install it in the cabinet.
(2) Installation of water inlet tee and ball valve:
1. Close and confirm that the main valve is closed (open the faucet without running water)
2, the old pipeline should be very easy to damage, to remind the user, find an experienced person or the animal husbandry department to assist.
3. Remove the faucet, install the water inlet tee and the ball valve to wrap the raw material belt, and then install the faucet.
4. Confirm that there is no water leakage after installation.
(3) Assembly machine
1. RO film, RO film direction, with two small sealing rings at one end, press the bottom by hand (can wipe a little Vaseline), can not use the cover to the top or squat. Check the seal ring for large defects. The seal on the cover must be placed on the membrane shell and coated with a small amount of Severin.
2. Install the filter element, first wrap the filter housing around the raw material strip, in order from right to left, 5 micron PP
Cotton, granular carbon, sintered activated carbon. PP cotton installation has no direction, granular activated carbon, sintered activated carbon with a rubber pad at one end corresponding to the direction of the head, and remove the heat shrink film outside the filter at the same time put the rubber pad, check the sealing surface, groove, seal ring for any defects, Apply some Vaseline to the seal ring and tighten with a special wrench.
(4) Installation of water ball valve:
Wrap the upper end of the water storage bucket with some raw material tape, then tighten the water storage bucket valve, and press it up, do not damage the screw, and do not use too much force to prevent the ball valve from cracking.
(5) Installation of gooseneck faucet:
1. If installed on the water tank, use a power drill to open the hole at a constant speed, the hole diameter is 11-16 mm, and install the gooseneck faucet directly.
2. If it is installed on the wall, fix the hanging piece, (the pipe left is left, the distance is more than 10 cm). Install the faucet and fix the decoration piece firmly.
(6), pipeline connection:
The fittings include 4 to 5 meters long tubes, which are used for 4 places respectively, which are tap water inlet, pressure barrel take-over, gooseneck faucet take-over, and waste water discharge pipe. The installer must make a reasonable layout for easy maintenance.
1 Plastic parts: the pipe mouth is flat, the nut is put on, the pipe plug is good (the strength of the pipe is strengthened), and the nut is 2-3 mm long.
2 Inlet water ball valve and inlet pipe installation, cut the pipe mouth flat, put metal nut, then insert the plastic pipe into the water outlet end of the water ball valve, tighten the nut, do not use too much force, so as not to break the pipe card 3 : The pipe is cut flat, put on the metal nut, the mud dragon sleeve, the nut grows out at the pipe mouth, the nut grows 2-3 mm, the pipe plug is inserted, and the tightening is stronger than the water ball valve.
4 The waste water connection pipe is connected to the sewage pipe and sealed.
5 After connecting, straighten out the pipe.
Eight, the pure water machine debugging (1) purpose, the last comprehensive adjustment of the machine, check to prevent errors.
(II) Method and role
1. Open the inlet ball valve and find the gooseneck faucet. After filling the water, turn on the power; 1, 2, 4, 5 lights, then 1, 2, 3, 5, the light is on, after 1 minute, 1, 3 5, the light is on, the water volume of the sewage drain pipe is changed from large to small, which proves that the flushing solenoid valve is intact and effective. The check valve is unobstructed.
2. After the standby device is normally water-making, (the water flow is stable, no air bubbles), close the ball valve on the water storage tank, close the gooseneck faucet, and later, the pure water machine stops, which proves that the shutdown function of the high-voltage switch is intact; Gradually stop, prove that the water inlet solenoid valve is intact, effective: the high pressure pump should not be operated frequently, which proves that the check valve is closed tightly.
3, open the goose faucet, the water pressure is gradually reduced, after a few seconds, the pure machine normal water production, prove that the high-voltage switch boot function is intact and effective. In the normal water production process, the pure wastewater volume flow rate is uniform, which proves that the water inlet solenoid valve is good.
4. Repeat the above work 2-3 times.
5. Close the inlet ball valve, the pure water machine stops, open the inlet ball valve. After several tens of seconds, the pure water machine is turned on, which proves that the low-pressure switch of the pure water machine is functioning properly and effectively, repeating 2-3 times.
6. After everything is normal, fill the pressure storage tank with pure water, open the goose faucet, and rinse the pure water to remove the activated carbon until the water is clean. Turn off the goose faucet to let the machine water normally.
Pay Manager 14:26:12
Nine, pure water machine fault diagnosis and elimination (1) no water
1. Water and electricity are normal.
2, high pressure pump transfer, with or without waste water, if there is waste water, water inlet system, drainage system, no problem, check valve stuck, no pure water out of the faucet, whether the film is scrapped in advance, or has been used, water is not Smooth or not water; there is no blockage in other places.
3. If there is no waste water, check the water inlet solenoid valve, whether it can not be opened, the water can not pass, and check whether the filter element has been blocked, to the replacement period.
4, the pump does not turn, there is no water, always 3, 4, 5 lights, check the high voltage switch, (short circuit method).
5. The pump has no pressure (the pump is also running).
6. The circuit does not check the circuit normally.
(2) The water storage tank is full but does not stop to check the high-voltage switch. If the pressure is too high, if it is too high, adjust it to 2.8-3Kg/cm. (The water pressure gauge is selected, the range of 1/3-2/3 is the most accurate. The measurement is multiplied by 2,0.6 Ma.) The pressure is not too large, the pressure is too high, and the inlet pressure is increased accordingly, so that the wastewater will increase. The indirect reaction increases and the wastewater increases. The pressure of the indirect reaction high pressure pump is less than 3Km/cm2a, the pressure of the high pressure pump is not enough, and the pressure of the high pressure pump is too low, and the normal pressure should be 6-8Kg/cm2.
(3), no water does not start 4, 5 lights, short circuit method check high voltage switch. 3, 5 lights, open circuit check the low voltage switch.
(4) After the shutdown, the wastewater does not stop entering the water. The solenoid valve is not closed tightly, or it is reversed. The backstop valve does not stop returning water. In both cases, the waste water is different. The former tap water and the latter one is pure water. The water quality is different: the amount of water is different. The former type is relatively rushing, and the latter type of flow is small. Because the backstop valve causes non-stop waste water, the water tank barrel valve can be closed, and the waste water flow stops, which can be judged.
(5) The machine frequently starts the backstop valve to return water, and the high pressure switch pressure is too high.
(6) Judging its fault according to the action of each component.
1, high voltage switch:
The water is not stopped, and the pressure tank is short of water and does not start.
2. Check valve:
Failure 1. The wastewater does not stop and the water quality is good;
Fault 2, the high pressure pump runs without pure water;
Fault three, the check valve spool is stuck but pure water, the pure water machine is running normally, the indicator light is normal, but no water is produced.
3. Inlet water solenoid valve:
Failure 1. The wastewater is not closed, the water quality is poor, and the flow rate is large.
Fault 2, the water inlet solenoid valve can not be opened, does not enter the water, resulting in no pure water, the characteristic is that the computer board shows normal, the pump is running normally, and the wastewater is not.
4, low voltage switch:
One of the faults, no water stop after stopping the water, the computer board is 1, 3, 5 lights on, the open circuit method.
The second problem is that after water, the water pressure is normal, no power on, short circuit method.
5. Flush the solenoid valve:
One of the faults, no flushing, the solenoid valve can not be opened.
The second problem is that the shutdown is not strict and the wastewater is flowing. When the wastewater flow rate is large, the pressure will be reduced a lot, and in severe cases, no water will be produced.
6, high pressure pump:
The pressure is not enough to produce water properly. Without stopping the machine, the shutdown pressure of the high-voltage switch is not reached, and the water quality is not normal.
7, pressure bucket:
One of the failures is that there is no water or less water. First, the water is leaking, the water is out of the mouth, and it cannot be repaired.
The second fault, the yellow water, the PE liner rupture, causing the water to directly contact the steel drum, rust, surface and taste.
8, R. O film:
The removal rate is low, 90% lower, and abnormal. Over time, the increase in water consumption, removal rate, and water production gradually decrease.
9, filter:
One of the faults, blockage, the first level of blockage, the computer board only lights the fifth light, (green moss, bacteria, sediment blockage). The water is stopped, the second and third levels are blocked, the 1, 3, and 5 lights are all on, and there is no waste water to make water. The same as the water inlet solenoid valve is not opened, the segmentation method is excluded.
The second fault, the fifth level is blocked, the water is full, there is no pure water, and the segmentation method is excluded.
The third fault, the filter element fails, affecting the life and effect of various parts of the machine.
10. The computer board indicates the working status and redistributes the circuit. Four lights or more than four lights are on for a long time (more than 2 minutes), there is a problem with the computer board: 3, 4, 5 lights are on, but the water is not full, the problem of the high voltage switch is eliminated, and the computer board is faulty. 1, 3, 4, 5 lights, the computer board itself is faulty.
Schedule: 1
Trouble phenomenon Fault cause Trouble-shooting No water supply No electricity Repair power supply high and low pressure valve failure Repair or replace the pressure pump damage Repair or replace the flush switch in the flush position Close the flush switch new machine (flush switch)
Water stop or water pressure is too low to restore the water supply booster pump and the customer to explain that the water inlet solenoid valve is damaged (but the water can not be opened) Replace the solenoid valve pre-filter or RO membrane blockage step by step inspection cleaning or replacement of the pipeline connection error control Flowchart reconnection
2,
Fault phenomenon Fault cause Fault treatment Water production is small Influent flow rate Small adjustment Large inlet pressure Pre- or post-filter plug is checked step by step and processed. Booster pump pressure is measured with a pressure gauge. If the pressure is small, repair or replace (5) -8Kg/cm2)
Flush switch not flushed (new machine) open flush switch
RO membrane blockage Clean or replace RO membrane
3,
Trouble phenomenon Fault cause The faulty machine starts frequently. The check valve fails. Replace the check valve. The pressure difference of the high pressure valve is too small (pressure difference is generally 1KgF/cm2). Replace the high pressure valve.
4,
Trouble phenomenon Fault cause The water in the tank is not filled with water or water. The water inlet pressure switch does not open. The preset pressure in the water inlet tank disappears.
5,
Symptoms Fault Causes Trouble in pure water with odor or poor mouthfeel. Pre-activated carbon failure. Replacement of new post-activated carbon failure. Replacement of new water storage pressure tank liner. Replacement pressure tank.
RO membrane blockage Clean or replace RO membrane
6,
Fault phenomenon Fault reason Faulty pure water TDS value is high (pure water TDS value ≤ raw water TDS value × 10%) removal rate ≥ 90%
The TDS value of pure water is high. The pre-filter element is not replaced in time. It is replaced step by step until the activated carbon fails after reaching the standard. Replace with new one.
RO membrane failure Replace RO membrane
RO membrane is placed in the membrane shell and the seal is not tight. Update placement (mainly new machine)
The newly installed machine is not flushed with the activated carbon. Increase the flushing time. The water pressure tank liner is leaking. Replace the pressure tank.
7,
Fault phenomenon Fault reason Fault handling water storage tank less water High pressure valve pressure is too low (high pressure switch) Use pressure gauge to measure, if the pressure is small, repair or replace the installation machine process 1, water inlet tee and ball valve.
Second, install RO membrane.
Third, with 5 micron PP cotton, granular activated carbon, sintered activated carbon.
4. Punch holes at the machine and at the gooseneck faucet.
Fifth, install pressure buckets.
Six, with goose neck faucet.
Seven, the machine, the connection of water pipes.
(1) 5 micron PP cotton --- water three-way ball valve.
(2) Wastewater Department---Sewage Pipeline.
(3) Pressure barrel---post-activated carbon (right end).
(4) Rear activated carbon (left end) --- gooseneck faucet.
Eight, the water pipe line, keep the water pipe line consistent.
Nine, debugging.
Pure water machine installation technical class and the working principle of each accessory fault (continued)