1. After 200~300 hours of operation, the oil should be changed for the first time. In the future use, the quality of the oil should be checked regularly. For the mixed impurities or deteriorated oil, it must be replaced in time. Under normal circumstances, for speed-reducing equipment that has been working continuously for a long time, replace the new oil with 5000 hours of operation or once a year. The gearbox that has been deactivated for a long time should be replaced with a new oil before the re-run. The oil should be added to the same oil as the original grade. It must not be mixed with different grades of oil. Oils with the same grade and different viscosity are allowed to be mixed.

2. When changing oil, wait for the deceleration equipment to cool down without burning danger, but still keep warm, because after the complete cooling, the viscosity of the oil increases and it is difficult to drain. Note: Turn off the power supply of the transmission to prevent unintentional power-on!

3. During work, when the temperature rise of oil exceeds 80 °C or the temperature of the oil pool exceeds 100 °C and abnormal noise is generated, stop using it. Check the cause, remove the fault, and replace the lubricating oil before continuing operation. .

4. The user should have reasonable rules for the use and maintenance. The operation of the reducer and the problems found in the inspection should be carefully recorded. The above provisions should be strictly implemented.