Identification of the construction quality of kitchen ceiling decoration

Kitchen cabinet installation quality identification method:

1 You must first draw a good plan and then construct it. You can't just build with experience and feeling.

The width of the countertops of 2 counters shall not be less than 500 mm and the height shall be 800 mm (including the thickness of the countertops). The height of the gas cooktop shall not be greater than 700 mm (including the thickness of the countertop paving material), and the width shall not be less than 500 mm. Cabinet cabinet floor should not be less than 100 mm from the ground. {TodayHot}

(3) The door frame and door leaf of the cabinet and door leaf or mixed structure cabinet made of blockboard shall be connected by ramming, glued together with glue, and tightened with glue wedge.

Hanging cabinet construction quality appraisal method:

1 Wooden blocks must be connected to each other with rakes, tightly fitted, cemented with rubber and tightened with plastic wedges.

2 The panel is firm and tight, and the surface of the veneer cannot play drums or bumps.

3 The cabinet surface is smooth, with neat corners, no burr and external hammer. Cabinet door switch is flexible. The cabinet is overall straight, firm and does not deform.

4 The underside of the hanging cabinet is no less than 2 meters from the ground. Hanging cabinet door should generally be split plywood doors. The width of each pair of doors should not exceed 1 meter. The depth of the cabinet shall not exceed 450 mm, and the depth of the cabinet shall not be greater than 620 mm. {HotTag}

5 The paint applied on the surfaces of cabinets and wall cabinets shall be smooth, smooth, free from brush marks, uniform in color, and free from defects such as paint leakage, sand particles, spotting, and falling. Strabismus without glue marks. Apply water lacquer, wood grain should be clear. The color of the wall cabinet wall cabinet should be consistent with the color of the wall surface or doors and windows to receive the harmonious effect.

Ceiling construction quality appraisal method:

1 The types, specifications, colors and basic structure of the materials used in the ceiling project shall be in accordance with design requirements or housing requirements.

2 The lamp trough, diagonal braces, and scissors braces in the ceiling should be properly arranged according to the project conditions. The light fixtures can be hung on the main keel or the additional keel. Heavy-duty lamps or ceiling fans must not be attached to the keel of the ceiling. Separate hooks should be provided on the base roof.

3 The distance between the boom and the end of the main keel must not exceed 300 mm. When the boom and the electrical equipment meet, the structure of the hoisting point should be adjusted or additional booms should be installed to ensure the ceiling quality.

4 The connection between the cover panel and the keel should be tight and the surface should be flat. There should be no defects such as pollution, folds, missing edges, and hammers. The joints should be even and the affixed cover panel should not be delaminated. The cover panel must have no leakage, penetration, or warping angle.

Aluminum alloy doors and windows installation quality identification method:

1 The installed aluminum alloy doors and windows should be closed tightly, and the gap should be uniform; the parallelism between the door and window fan and the frame or the adjacent edge of the adjacent fan should not exceed 2 mm, and the opening is flexible and easy to use.

2 Sliding doors and windows, see if the glideslope is installed flat, be careful not to bump, gently push the doors and windows, should slide freely.

(3) The aluminum frame and the horizontal frame of the balcony aluminum window must be firmly fixed on the balcony railing and the top of the balcony. Generally, it is fixed in the concrete by nails or rivets, and the angle steel reinforced by painting is used for fixing. Can not be fixed on the brick wall, can not use a wooden wedge up and down the vertical stand instead of nail gun fixed. The gap between the upper glideslope and the top guardrail should be filled with cement mortar to prevent rainwater from pouring into the room.

4 The thickness of the aluminum alloy window profile should not be less than 1.4 mm, and the wall thickness of the door profile should not be less than 2 mm. The thickness of the connection between the aluminum alloy door frame and the wall shall not be less than 1.5 mm. The window section of the aluminum alloy window should not be less than the 55 series, the push window should not be smaller than the 75 series, and the closed window of the balcony should not be smaller than the 75 series.

Gas pipeline construction quality appraisal method:

1 The pipeline is arranged properly. The threads of the teeth are of moderate depth and arranged neatly. The teeth of the pipe are 8 teeth and 5 teeth are twisted into the tube. Thick white lacquer is used for pipe connection and the connector is tightened.

2 Water heater inlet, gas inlet should be installed valves.

3 Water heaters and other appliances are installed smoothly, safely, easy to operate, and the ignition is normal

Windows and doors aisle ceiling window aluminum alloy paint switch cabinet cupboard door cabinet ceiling fan light kitchen cabinet door closet door kitchen sliding door closet cabinet door

Pastry Basting Brush

Pastry basting brush is a cooking tool for speading the oil, butter or glaze on food. It can be made with natural bristles or synthetic fiber. Its brush hair is usually made of durable and healthy material. The handle canbe wood or plastic, similar to Paint Brush, but the handle length differs. It depends on your detailed requirement. It is perfect for cake baking, BBQ and grilling.