At present, in the process of isolation and preparation of various stem cells from various tissue sources, Centrifuge Tubes with a volume of 15ml and 50ml are used. centrifuge tube rack bulk,tube rack for centrifuge,rack for centrifuge tube Yong Yue Medical Technology(Kunshan) Co.,Ltd , https://www.yonyue.com
Dimension Range of Sintered NdFeB
Â
Length (OD)Â mm
Width (ID)Â mm
Thickness (mm)
Min.
Max.
Min.
Max.
Min.
Max.
Block
1
150
1
100
0.5
150
Ring
1
180
1
140
0.6
50
Disc/Bar
1
150
 Â
 Â
0.6
50
Â
Length
Chord Length
Â
Â
Min.
Max
Min.
Max.
Â
Â
Segment
3
50
5
150
 Â
 Â
Magnetic Characteristics and Physical Properties of Sintered NdFeB
Grade
Remanence
Coercive Force
Intrinsic Coercive force
Max Energy Product
Highest Work temperature
Br
Hcb
Hci
(BH) max
T
KGs
KOe
KA/m
KOe
KA/m
MGOe
KJ/m
ºC
N35
1.16-1.22
11.6-12.2
11
876
12
955
33-36
263-287
80
N38
1.22-1.27
12.2-12.7
11
876
12
955
36-39
287-310
80
N40
1.25-1.31
12.5-1.31
11
876
12
955
38-41
303-326
80
N42
1.28-1.34
12.8-13.4
11
876
12
955
40-43
318-342
80
N45
1.32-1.38
13.2-13.8
11
876
12
955
43-46
342-366
80
N48
1.37-14.3
13.7-14.3
10.5
836
11.5
915
46-49
366-390
80
N50
1.40-1.46
14.0-14.6
10.5
836
11.5
915
48-51
382-406
80
N52
1.43-1.49
14.3-14.9
10.5
836
11.5
915
50-53
398-422
80
N30M
1.08-1.14
10.8-11.4
9.8
780
14
1114
28-31
223-247
100
N33M
1.14-1.18
11.4-11.8
10.3
820
14
1114
31-33
247-263
100
N35M
1.6-1.22
11.6-12.2
10.6
845
14
1114
33-36
263-287
100
N38M
1.23-1.27
12.3-12.7
11
876
14
1114
38-41
303-326
100
N40M
1.25-1.31
12.5-13.1
11.5
912
14
1114
38-41
303-326
100
N42M
1.28-1.34
12.8-13.4
11.8
938
14
1114
40-43
318-342
100
N45M
1.32-1.38
13.2-13.8
12.2
976
14
1114
43-46
342-366
100
N48M
1.37-1.43
13.7-14.3
12.7
1012
13.5
1075
46-49
366-390
100
N50M
1.40-1.46
14.0-14.6
13
1035
13.5
1075
48-51
382-406
100
N35H
1.16-1.22
11.6-12.2
10.6
845
17
1353
33-36
263-287
120
N38H
1.21-1.27
12.1-12.7
11.1
886
17
1353
36-39
287-310
120
N40H
1.25-1.31
12.5-13.1
11.5
912
17
1353
38-41
303-326
120
N42H
1.28-1.34
12.8-13.4
11.8
938
16.5
1313
40-43
318-342
120
N45H
1.32-1.38
13.2-13.8
12.2
976
16
1274
43-46
342-366
120
N30SH
1.07-1.14
10.7-11.4
9.7
772
20
1592
28-31
223-247
150
N33SH
1.22-1.19
1.14-1.18
10.2
816
20
1592
31-34
247-271
150
N35SH
1.16-1.22
11.6-12.2
10.6
845
20
1592
33-36
263-287
150
N38SH
1.21-12.7
12.1-12.7
11.1
886
20
1592
36-39
278-310
150
N40SH
1.25-1.31
12.5-13.1
11.5
912
20
1592
38-41
302-326
150
N42SH
1.28-1.34
12.8-13.4
11.8
938
20
1592
40-43
318-342
150
N30UH
1.07-1.14
10.7-11.4
9.7
772
25
1990
28-31
223-247
180
N33UH
1.12-1.19
11.2-11.9
10.2
816
25
1991
31-34
247-271
180
N35UH
1.16-1.22
11.6-12.2
10.6
845
24
1910
33-36
263-287
180
N38UH
1.21-1.27
12.1-12.7
11.1
886
24
1910
36-39
287-310
180
N30EH
1.07-1.14
10.7-11.4
9.7
772
30
2388
28-31
223-247
200
N33EH
1.12-1.19
11.2-11.9
10.2
816
30
2388
31-34
247-271
200
N35EH
1.16-1.22
11.6-12.2
10.6
845
30
2388
33-36
263-287
200
Physical Properties of Sintered NdFeB Material
Properties
Unit
Parameter
Curie Point
ºC
310-340
((Br)/ (%/K)Temp.Coeff.of Br
%ºC
-0.08 ~ - 0.12
(β(Hcj/%/K)Temp.Coeff.of Hcj
%ºC
-0.42 ~ -0.70
Density
g/cm3
≥7.3
Vickers Hardness
Hv
600
Bending strength
Mpa
250
Tensile strength
Mpa
80
Compressive strength
Mpa
1050
Electrical resistivity
μΩcm
150
Thermal conductivity
W/(m.ºC)
6 ~8
Â
Â
Â
It is one of the low-value consumables with high usage rate. It is generally installed on a dry foam rack with the package or in bulk. When used, it is taken out by the operator and placed on the plastic centrifuge tube rack in the ultra-clean workbench. The common centrifuge tube rack can only make the centrifuge tube stand upright. When transferring liquid or needing centrifugation, the operator should hold the centrifuge tube in the left and the night gun or aspirator in the right. If it is necessary to transfer a large amount of liquid reagents or perform gradient centrifugation operations, such as density gradient centrifugation to separate mononuclear cells, the operator needs to hold the centrifuge tube with the right hand for a long time and tilt the centrifuge tube, which often causes the operator's wrist joint pain. At the same time, it will also affect the liquid superposition effect, which will easily lead to the mixing of liquids of different densities, resulting in the failure of the experiment.